Cảm biến lưu lượng Keyence FD-XS1

CÔNG TY TNHH F&E

Cảm biến lưu lượng Keyence FD-XS1

Sensor head Maximum rated flow rate 1 L/min
SKU: FD-XS1
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

  • FD-XS1
  • 1055
  • Liên hệ
  • Báo giá
Model FD-XS1
Supported pipe materials Metal pipes, Plastic pipes (soft/hard) *1
Supported fluids Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1
Supported fluid temperature 0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)
Clamp set model Plastic pipe/tube attachment FD-XC1R1, FD-XC1R2
Metal pipe attachment FD-XC1M*2
Maximum rated flow rate 0 to 1000 mL/min
Zero cut flow rate 20 mL/min*3 (variable, default)
Display resolution Instantaneous flow rate 0.1/1/10 mL/min (Displayed on controller)
Shot amount 0.001/0.01/0.1/1 mL (Displayed on controller)
Repeatability Plastic pipe/tube attachment Response time: 50 ms F.S. ± 0.6 %*4*5
Instantaneous flow rate ±6 mL/min*4*5
Response time: 500 ms ±1.9 mL/min*4
Metal pipe attachment Response time: 50 ms F.S. ± 1 %*4*5
Instantaneous flow rate ±10 mL/min*4*5
Response time: 500 ms ±3.2 mL/min*4
Hysteresis Variable
Integrated unit display 0.1/1/10/100/1000/10000 mL (displayed on controller)
Display method Status indicator
Environmental resistance Enclosure rating IP65/IP67 (IEC60529) , IP68G (JIS C0920) *6
Ambient temperature 0 to 60 °C (No freezing) 32 to 140 °F
Relative humidity 35 % to 85 %RH (No condensation)
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm 0.06 “, 2 hours each for X,Y,Z direction
Shock resistance 50 G 11 ms 3 times each for X,Y,Z direction
Material Sensor head Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM
Clamp set For plastic pipe Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7
For metal pipe Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7
Weight Approx. 230 g
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1: approx. 0.5 mm 0.02″, FD-XS8: approx. 1 mm 0.04″, FD-XS20: approx. 1 0.04″ to 2 mm 0.08″. FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range.
*5 The longer the response time is set, the more repeatability is improved. As a guideline, use √ (50 ms/response time) times.
*6 The connector part of the sensor head cable is IP65/IP67.

Thông tin bổ sung

Thương hiệu

Keyence

Thời gian bảo hành

1 Năm

Yêu cầu tư vấn(+84)911031155(Call/Zalo)
Sản phẩm cùng loại
Zalo
Hotline
(+84)911031155 (+84)911031155