Cảm biến lưu lượng Keyence FD-H32

CÔNG TY TNHH F&E

Cảm biến lưu lượng Keyence FD-H32

Flow Sensors Standard model 25A/32A
SKU: FD-H32
Hãng sản xuất: Keyence
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Chứng từ: CO/CQ, hóa đơn VAT

  • FD-H32
  • 1429
  • Liên hệ
  • Báo giá
Model FD-H32
Type Standard model
Supported pipe diameter 1″ (25A), ø28–37 ø1.10″-1.46″
1 1/4″ (32A), ø37–44 ø1.46″-1.73″
Supported pipe materials Metal piping, hard plastic piping*1
Supported fluids All fluids (water, oil, chemicals, etc.)*1
Supported fluid temperature 0–85°C 32–185°F (no freezing on pipe surface)*2
Maximum rated flow 1″ (25A) : 200 L/min 52.8 gal/min
1 1/4″ (32A) : 300 L/min 79.3 gal/min
Zero cut flow rate 1.0 L/min 0.3 gal/min (variable, initial value)
Detection principle Delta TOF + Pulse Doppler
Function for automatic correction for speed of sound in liquid Yes
Display QVGA 2.0 model: color LCD, status indicator light
Display update cycle Approx. 10 times/second
Display resolution Instantaneous flow 0.01/0.1/1 (L/min) (default value: 1)
Integrated flow 0.01/0.1/1 (L) (default value: 1; up to 8 digits)
Response time 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s
Measurement accuracy Between 10 and 100% of F.S.: ±3.0% of RD*3*4
Between 0 and 10% of F.S.: ±0.3% of F.S.*3*4
Repeatability 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*3*5
Hysteresis Variable
Flow units L/min m3/h G/min
Pulse output increments (L) 0.02–999.99
Pipe temperature measurement accuracy ±2.0°C ±3.5°F (pipe temperature 0–50°C 32–122°F) , ±3.0°C ±5.4°F (pipe temperature 50–85°C 122–185°F) (ambient temperature of 25°C 77°F)*3
Network support IO-Link*6
Heat calculation function Unit MJ/h kW kBTU/h*7
Display resolution Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*7
Pulse output increments (MJ) 0.02–999.99*7
Data accumulation Accumulation period Approx. 1 year
Data reading USB2.0
Power I/O connector M12 8-pin connector (male)
I/O (switchable) Output (Ch1/2/3/4) Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error output
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less
Analog output (Ch1/2) 4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less
External input (Ch2/3) Integrated reset input / flow-rate zero input / zero-point adjustment input / bank input
Short circuit current: 1.5 mA or less; input time: 20 ms or more
Power supply Power voltage 20–30 VDC, ripple (P-P) 10% included, Class 2/LPS
Current consumption 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*8
Protection circuit Protection against reverse power connection, power supply surges, output short circuits, and output surges
Environmental resistance Enclosure rating IP65/67 (IEC 60529)*9
Ambient temperature Sensor head: −20 to +60°C –4 to +140°F (no freezing); Display unit: −20 to +50°C –4 to +122°F (no freezing)*2
Relative humidity 35–85% RH (no condensation)
Vibration resistance 10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions
Shock resistance 100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes
Material Display unit Body: PPS/PET/POM; Display window: PAR
Sensor head Body: PPS/PET/PAR/SUS304
Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7
Weight approx. 620 g 21.87 oz
*1 For fluids through which ultrasonic waves propagate, and which do not contain a large quantity of bubbles. Detection may be unstable depending on the type and condition of the pipe.
*2 When the display unit is mounted directly on the sensor head, there is a de-rating according to the ambient temperature and fluid temperature.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Measurement error may occur depending on the type and condition of the customer’s pipes, the type of fluid, the fluid temperature and other factors.
*4 This is the value for when the zero point is adjusted, for a constant 25°C 77°F environment, taking into account the linearity and span error.
*5 In a state where flow velocity distribution is stable. Does not include pulsation and fluctuations in flow velocity distribution due to equipment factors. Please also convert the given F.S. (full scale) using the rated flow range.
*6 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*7 Can be used when two temperature sensors (sold separately) are connected.
*8 640 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (up to a maximum of 830 mA or less).
*9 When a USB connection is in use, IP65/67 compliance is impaired.